Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement

Product Specifications Select Now
3.78L
3.78L
Product Details
Customization: Available
Application: Construction
Bonding Function: Other
Secured Trading Service
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 8 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (13)
  • Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
  • Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
  • Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
  • Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Application Scenarios
  • How to use
  • Company Profile
  • Recommend products
  • Customer feedback
  • FAQ
Overview

Basic Info.

Model NO.
AntiStatic Floor Wax
Color
White
Composition
Organic Material
Morphology
Water Emulsion
Transport Package
Carton
Specification
3.78L
Trademark
3M
Origin
USA
Production Capacity
1000

Product Description

Product Description
Effective Static Control: Formulated to maintain a consistent static-dissipative path, protecting sensitive electronics from ESD damage.
3M Quality & Reliability: Backed by 3M's expertise in surface protection and static control technology.
Durable & Long-Lasting: High-traffic resistance reduces the frequency of rewaxing, lowering long-term maintenance costs.
Enhances Appearance: Provides a high-gloss, professional finish that improves floor aesthetics.
Easy Application & Maintenance: Water-based formula allows for easy application, recoating, and routine cleaning.
Safe & Low Odor: Low VOCs compared to solvent-based alternatives, suitable for occupied spaces.
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Specification
Brand
3M
CAS No.
Proprietary blend (specific CAS not applicable for commercial formula).
Color
Milky white (dries clear to glossy).
Additives
Conductive compounds, wear-resistant agents, gloss enhancers.
Application
Applied by mop, spray buffing, or automatic floor machine on sealed floors.
General Composition
Acrylic polymers, conductive materials (e.g., metallic salts, carbon), surfactants, water.
Specification
Complies with relevant ESD standards (e.g., ANSI/ESD S20.20); surface resistance typically in the dissipative range (e.g., 10^6 to 10^9 ohms).
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Application Scenarios
Electronics Manufacturing: Cleanrooms, assembly areas, PCB handling zones.
Critical Facilities: Data centers, server rooms, telecom switch rooms.
Healthcare: Hospital operating rooms, diagnostic labs (where static may affect equipment).
Industrial & Laboratory: Precision instrument rooms, chemical processing areas with static ignition risks.
General Office & Commercial Spaces requiring both aesthetics and static control.
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
How to use
1.Preparation: Thoroughly clean the floor with a neutral cleaner and let it dry completely. Ensure the floor is sealed.
2.Application: Stir the wax well. Apply a thin, even coat using a clean mop, applicator, or spray buffing machine. Avoid puddles.
3.Drying: Allow to dry completely (typically 20-30 minutes under good ventilation). Do not walk on it during drying.
4.Additional Coats: For higher gloss and durability, apply 2-3 thin coats, allowing full drying between each coat.
5.Maintenance: Regularly clean with a neutral pH cleaner. Recoat as needed when gloss or anti-static performance diminishes.
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Company Profile
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Recommend products
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Customer feedback
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
Xqh241 3m Antistatic Floor Coating Wax for Data Center Hospital Laboratory ESD Safety Requirement
FAQ
Q: What is the difference between Antistatic and Conductive wax?
  A: Both control static. "Conductive" typically refers to lower resistance (e.g., 10^4-10^6 ohms), while "Antistatic/Dissipative" is higher (e.g., 10^6-10^9 ohms). Our product is designed for the dissipative range, suitable for most ESD protected areas.
Q: Can it be applied to any floor type?
  A: It is designed for sealed resilient floors (vinyl, linoleum, sealed concrete). Test on a small area first for compatibility. Not for unsealed wood or porous surfaces.
Q: How often should it be reapplied?
  A: Depends on traffic. Heavy areas may need re-coating every 3-6 months; lighter areas can last 6-12 months.
Q: Is it slip-resistant?
  A: It provides a standard gloss finish. For wet slip resistance, specific anti-slip additives or products would be required.
Q: How to test its anti-static performance?
  A: Use a surface resistance meter following standards like ANSI/ESD STM7.1 to measure resistance.